TRAINING ELECTRICAL POWER SYSTEM ANALYSIS

TRAINING ELECTRICAL POWER SYSTEM ANALYSIS

TRAINING ANALISIS SISTEM ELECTRICAL POWER

TRAINING ELECTRICAL POWER

training analisis sistem electrical power murah

Description & Objectives
DescriptionA Power System is predominantly in steady state operation or in a state that could with sufficient accuracy be regarded as steady state. In a power system there are always small load changes, switching actions, and other transients occurring so that in a strict mathematical sense most of the variables are varying with the time. However, these variations are most of the time so small that an algebraic, i.e. not time varying model of the power system is justified.

The purpose of this course is to develop a thorough understanding of power system analysis and design as well as the overall capabilities of Power Station. Class room discussion, and problem-solving has been designed to provide the analytical techniques necessary to solve a wide variety of practical problem

Objectives
* Verifying the adequacy of the power distribution system and it’s components.
* Recognize coordination related disturbances and outages.
* Collect the required data to perform a detailed coordination study.
* Derive complete protective device settings for some of the simpler electrical power systems that are consistent with NEC requirements.

Course Content
1. Introduction to Industrial Power Systems
2. Short Circuit Theory and Terminology

v  Effects of Short Circuits

v  Fault Current Sources

v  Machine Reactances

v  Fault Current Characteristics
1. Electrical Equipment Ratings

v Fuses

v Circuit Breakers

v Motor Starters

v Conductors and Bus
1. Balanced Fault Calculations
2. Coordination Fundamentals

v Procedures

v Data Collection

v Scaling Factors
1. Plotting Time/Current Curves

v Circuit Breakers

v Fuses

v Time Delay/Instantaneous Relays

v Relay Coordination Intervals
1. Equipment Protection and Coordination

v NEC and ANSI/IEEE Criteria

v  Conductors (Low and Medium Voltage)

v  Transformers

v  Motors e. Conductors (Low and Medium)

Instructor
Tugino, ST, MT(expert in Electrical Power System Analysis and Instrumentation)
Who Should Attend
This course is intended for anyone who must perform calculations, provide settings or approve the work performed by others. The trainee should be a graduate engineer or have the equivalent practical work experience in electrical power systems.
Method
Presentation, Discussion, Simulation, Case Study, and Evaluation

 Pelatihan Transindo Tahun 2019 :

 

Catatan : Jadwal tersebut dapat disesuaikan dengan kebutuhan calon peserta pelatihan.

 

Investasi dan Lokaspelatihan:

  • Yogyakarta, Hotel Neo Malioboro (7.500.000 IDR / participant)
  • Jakarta, Hotel Amaris Tendean (7.500.000 IDR / participant)
  • Bandung, Hotel Neo Dipatiukur (7.500.000 IDR / participant)
  • Bali, Hotel Ibis Kuta(7.500.000 IDR / participant)
  • Surabaya, Hotel Amaris, Ibis Style (7.500.000 IDR / participant)
  • Lombok, Sentosa Resort (7.500.000 IDR / participant)

Catatan : Apabila perusahaan membutuhkan paket in house training, anggaran investasi pelatihan dapat menyesuaikan dengan anggaran perusahaan.

Fasilitas :

  • FREE Airport pickup service (Gratis Antar jemput Hotel/Bandara/Stasiun/Terminal)
  • FREE Akomodasi Peserta ke tempat pelatihan .
  • Module / Handout
  • FREE Flashdisk
  • Sertifikat
  • FREE Bag or bagpackers (Tas Training)
  • Training Kit (Dokumentasi photo, Blocknote, ATK, etc)
  • 2xCoffe Break & 1 Lunch, Dinner
  • FREE Souvenir Exclusive
  • Training room full AC and Multimedia
Share your love

Newsletter Updates

Enter your email address below and subscribe to our newsletter

Leave a Reply

Your email address will not be published. Required fields are marked *

Tanyakan pada kami ?

Kami di sini untuk membantu Anda! Jangan ragu untuk menanyakan apapun kepada kami. Klik di bawah untuk memulai obrolan.

Client Development

Diyah

Online

Client Development

Rani Ahmad

Online

Diyah

Hai, tanyakan pada kami ? 00.00

Rani Ahmad

Hai, tanyakan pada kami ? 00.00